Strona 1 - MAINTENANCE

INSTALLATION,OPERATION&MAINTENANCEMANUALSINGLE PACKAGED ROOF TOP AIR CONDITIONERS'PT' SERIESMODELS: PT036 - PT360Part Number: 800-213-03

Strona 2 - Contents Page

UNIT DIMENSIONSPT180NOTE:1. All dimensions are in mm (dimensions in brackets are in inches).2. Service clearance should be 1200mm (4 feet) on all side

Strona 3 - MODEL DECODING

UNIT DIMENSIONSPT215 - PT240NOTE:1. All dimensions are in mm (dimensions in brackets are in inches).2. Service clearance should be 1200mm (4 feet) on

Strona 4 - INSPECTION FOR DAMAGE

UNIT DIMENSIONSPT300 - PT360NOTE:1. All dimensions are in mm (dimensions in brackets are in inches).2. Service clearance should be 1200mm (4 feet) on

Strona 5 - INSTALLATION INSTRUCTIONS

POWERSUPPLY380/415-3-50(4 wire)OPERATION INSTRUCTIONSSTART-UP INSPECTION & CHECK LISTAfter the installation is completed in all respect, the follo

Strona 6 - SERVICE CLEARANCE

MIN. MAX. FLA RLA LRA HP FLA kW FLA– – 15.2 205/6 7.6/9.1 16.4/18.3 20/20380/415-3-50 342 457 2.3 5.9 42 0.75 5.57.5/10* 11.4/15.2 21.1/25.9 25/3012*

Strona 7 - ELECTRIC HEATERS

ELECTRICAL DATA342 457 1.9– – 51 607.5/10 11.4/15.2 51/51 60/60 10*/12* 15.2/18.2 51/51 60/6015*/20* 22.8/30.4 51/51 60/6025*/30* 38/45.6

Strona 8 - UNIT DIMENSIONS

Performex-1TM CONTROLLER : OPERATION & FUNCTIONSThe COOLINE Packaged units are provided with technologically advanced new PerformexTM Controller

Strona 9 - SIDE VIEWFRONT VIEW

7. LEAD/LAG OPERATION: Whenever a compressor needs to be on, the controller will turn on the compressor withthe shorter accumulated run time provided

Strona 10 - TOP VIEW

MAINTENANCE INSTRUCTIONSAIRFLOW ADJUSTMENT (Applicable for PT075 - PT360 only)The airflow could be adjusted by adjusting pulleys of blower motor or be

Strona 11 - FRONT VIEW

FORCE SCALESPAN SCALERING"0"LARGE"0"RINGSMALLBELT SPANDEFLECTION =64BELT SPANBG - GROUNDFIELD WIRINGN - NEUTRAL TERMINAL BLOCKL3

Strona 12 - SIDE VIEW

Contents PageGeneralModel decoding ...

Strona 13 - OPERATION INSTRUCTIONS

PREVENTIVE MAINTENANCE SCHEDULE12XXXXXXXXXXXXXFREQUENCY OF MAINTENANCE, MONTHS(FIRST 4 YEARS)I T E MCAUTION: Disconnect power supply and allow all rot

Strona 14 - ELECTRICAL DATA

1. Check the power. Switch ON the circuit breaker.Replace fuse if it blown.2. Check wiring against diagram.3. Check and correct it.4. Replace it.1. R

Strona 15

TROUBLE SHOOTING CHART SYMPTOM CAUSES CHECK & CORRECTIVE MEASURE1. Low suction pressure2. High discharge pressure3. Less

Strona 16 - ELECTRONIC THERMOSTAT

JUMPER SETTING ON ECBDIP SWITCH SETTINGSHEATER DATA TABLE(SEE HEATER DATA TABLE)HEATER CONNECTION DETAILSTYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PT03

Strona 17 - PUMP DOWN CONTROL

2. SMOKE DETECTOR OPTIONCRANKCASE HEATER CONNECTION4. HPS CONNECTION OPTIONSTANDARD OPTIONS1. UVM OPTION3. VOLT FREE CONTACT OPTIONSA. UNIT ON & O

Strona 18 - MAINTENANCE INSTRUCTIONS

TYPICAL SCHEMATIC WIRING DIAGRAMNOTE: 1. Refer to next page for legend, notes & wiring diagram for optional items. 2. Refer to unit con

Strona 19 - DEFLECTION =

HPS OPTIONFAN MOTOR CONTROL CONNECTION(APPLICABLE FOR FM WITH T.O.P)NTO NTBL2TO HVTBBM WITH EXTERNAL OLRCONNECTION APPLICABLE FOR 1PH FM ONLYCRANKCASE

Strona 20 - (FIRST 4 YEARS)

HEATER DATA TABLECONNECTION FOR MANUEROP COMP. WITH SSPSCONNECTION FOR COMPRESSORWITH MOTOR OVERLOAD230V(SEE HEATER DATA TABLE)HEATER CONNECTION DETAI

Strona 21 - TROUBLE SHOOTING CHART

TYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PT180 - PT240 (Dual compressor units)LEGENDAR AUXILIARY RELAYAFS AIRFLOW SWITCHATB AUXILIARY TERMINAL BLOCKBM

Strona 22

TYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PT300 - PT360 (Dual compressor units)NOTE: 1. Refer to next page for legend, notes & wiring diagram for o

Strona 23 - DIP SWITCH SETTINGS

C : 1.5 HP ODPD : 2 HP ODPD : 2 HP ODPE : 3 HP ODPF : 3 HP TEFCG : 5 HP ODPH : 5 HP TEFCJ : 7.5 HP ODPK : 7.5 HP TEFCJ : 7.5 HP ODPK : 7.5 HP TEFCL :

Strona 24 - FACTORY INSTALLED B.M SPEED

TYPICAL SCHEMATIC WIRING DIAGRAMMODELS : PT300 - PT360 (Dual compressor units)LEGENDAR AUXILIARY RELAYAFS AIRFLOW SWITCHATB AUXILIARY TERMINAL BLOCKBM

Strona 25

MODEL NUMBER PT036L PT048L PT060L PT075L PT090 PT100L PT120L PT180L PT215LCOMPRESSOR800-684-08 800-672-52 800-643-01 800-674-78 800-684-09 800-672-52

Strona 26

GENERALGENERAL STATEMENTThis unit is from the PT series that was designed & built for the optimum performance. However, it is required that you be

Strona 27 - HEATER DATA TABLE

GENERALThese units are shipped completely assembled, charged, and wired. They do not require any field installation of refrigerant tubing.Units requir

Strona 28 - A) STANDARD CONNECTION

BCAEDBCDAATTENTION TO RIGGERS• Insert 2" nominal pipe through holes in the base rail as shown in the figure below for slings.• Holes in base rail

Strona 29

CONDENSATE DRAIN CONNECTION• Use standard PVC pipe with NPT connection for the condensate drain. Provide a 'P' trap immediately at the conde

Strona 30

UNIT DIMENSIONSPT036 - PT075ABCDEFGHJKLMPT036 - PT060 1460(57.48) 1025(40.35) 1430(56.3) 700(27.56) 163(6.42) 373(14.68) 250(9.84) 500(19.69) 57(2.24)

Strona 31 - PARTS LIST

UNIT DIMENSIONSPT090 - PT120NOTE:1. All dimensions are in mm (dimensions in brackets are in inches).2. Service clearance should be 1200mm (4 feet) on